AD 2001-04-04
Applicability
| Type | Manufacturer | Model | Details |
|---|---|---|---|
| aircraft | Dornier Luftfahrt GmbH | Dornier 228-100 | Airworthiness Directives; Dornier Luftfahrt GMBH Models 228-100, 228-101, 228-200, 228-201, 228-202, and 228-212 Airplanes |
| aircraft | Dornier Luftfahrt GmbH | Dornier 228-101 | Airworthiness Directives; Dornier Luftfahrt GMBH Models 228-100, 228-101, 228-200, 228-201, 228-202, and 228-212 Airplanes |
| aircraft | Dornier Luftfahrt GmbH | Dornier 228-200 | Airworthiness Directives; Dornier Luftfahrt GMBH Models 228-100, 228-101, 228-200, 228-201, 228-202, and 228-212 Airplanes |
| aircraft | Dornier Luftfahrt GmbH | Dornier 228-201 | Airworthiness Directives; Dornier Luftfahrt GMBH Models 228-100, 228-101, 228-200, 228-201, 228-202, and 228-212 Airplanes |
| aircraft | Dornier Luftfahrt GmbH | Dornier 228-202 | Airworthiness Directives; Dornier Luftfahrt GMBH Models 228-100, 228-101, 228-200, 228-201, 228-202, and 228-212 Airplanes |
| aircraft | Dornier Luftfahrt GmbH | Dornier 228-212 | Airworthiness Directives; Dornier Luftfahrt GMBH Models 228-100, 228-101, 228-200, 228-201, 228-202, and 228-212 Airplanes |
Unsafe Condition
Overheating of the windshield spray nozzle heating system, which could result in smoke in the cockpit and prompt the crew to initiate emergency actions.
AI-generated summary from the source AD text. Verify against the official source before acting.
Required Actions
Deactivate the windshield spray nozzle heating elements by cutting wire ME16F20 at the splice at frame 7, cap and stow cables. Do not install windshield spray nozzle option SCN 3109 on affected airplanes.
AI-generated summary from the source AD text. Verify against the official source before acting.
Compliance Time
Within the next 100 hours time-in-service after April 6, 2001, unless already accomplished.
AI-generated summary from the source AD text. Verify against the official source before acting.
Affected Aircraft
Dornier Luftfahrt GMBH Models 228-100, 228-101, 228-200, 228-201, 228-202, and 228-212 airplanes, all serial numbers, with windshield spray nozzle option SCN 3109 installed.
AI-generated summary from the source AD text. Verify against the official source before acting.
Federal Register Abstract
This amendment adopts a new airworthiness directive (AD) that applies to all Dornier Luftfahrt GMBH (Dornier) Models 228-100, 228- 101, 228-200, 228-201, 228-202, and 228-212 airplanes that have windshield spray nozzle option SCN 3109 installed. This AD requires you to deactivate the windshield spray nozzle heating elements. This AD is the result of mandatory continuing airworthiness information (MCAI) issued by the airworthiness authority for Germany. The actions specified by this AD are intended to prevent the windshield spray nozzle heating system from overheating, which could result in smoke in the cockpit and prompt the crew to initiate emergency actions.
Document Text
Show stored source text (verify against official source)
[Federal Register Volume 66, Number 35 (Wednesday, February 21, 2001)]
[Rules and Regulations]
[Pages 10963-10965]
From the Federal Register Online via the Government Publishing Office [<a href="http://www.gpo.gov">www.gpo.gov</a>]
[FR Doc No: 01-4048]
-----------------------------------------------------------------------
DEPARTMENT OF TRANSPORTATION
Federal Aviation Administration
14 CFR Part 39
[Docket No. 99-CE-19-AD; Amendment 39-12122; AD 2001-04-04]
RIN 2120-AA64
Airworthiness Directives; Dornier Luftfahrt GMBH Models 228-100,
228-101, 228-200, 228-201, 228-202, and 228-212 Airplanes
AGENCY: Federal Aviation Administration, DOT.
ACTION: Final rule.
-----------------------------------------------------------------------
SUMMARY: This amendment adopts a new airworthiness directive (AD) that
applies to all Dornier Luftfahrt GMBH (Dornier) Models 228-100, 228-
101, 228-200, 228-201, 228-202, and 228-212 airplanes that have
windshield spray nozzle option SCN 3109 installed. This AD requires you
to deactivate the windshield spray nozzle heating elements. This AD is
the result of mandatory continuing airworthiness information (MCAI)
issued by the airworthiness authority for Germany. The actions
specified by this AD are intended to prevent the windshield spray
nozzle heating system from overheating, which could result in smoke in
the cockpit and prompt the crew to initiate emergency actions.
EFFECTIVE DATE: This AD becomes effective on April 6, 2001.
ADDRESSES: You may get the service information referenced in this AD
from Dornier Luftfahrt GmbH, Product Support, P.O. Box 1103, D-82230
Wessling, Federal Republic of Germany; telephone: (08153) 302631;
facsimile: (08153) 304463. You may examine this information at the
Federal Aviation Administration (FAA), Central Region, Office of the
Regional Counsel, Attention: Rules Docket No. 99-CE-19-AD, 901 Locust,
Room 506, Kansas City, Missouri 64106.
FOR FURTHER INFORMATION CONTACT: Karl Schletzbaum, Aerospace Engineer,
FAA, Small Airplane Directorate, 901 Locust, Room 301, Kansas City,
Missouri 64106; telephone: (816) 329-4146; facsimile: (816) 329-4090.
SUPPLEMENTARY INFORMATION:
Discussion
What events have caused this AD? The Luftfahrt-Bundesamt (LBA),
which is the airworthiness authority for Germany, notified FAA that an
unsafe condition may exist on all Dornier Models 228-100, 228-101, 228-
200, 228-201, 228-202, and 228-212
[[Page 10964]]
airplanes. The LBA reported an incident where the windshield spray
nozzle overheated and generated smoke in the cockpit. This prompted the
crew to initiate an emergency evacuation during engine start.
The airplane had windshield spray nozzle option SCN 3109 installed.
What are the consequences if the condition is not corrected? If
this system overheats, smoke could enter the cockpit and prompt the
crew to initiate emergency actions.
Has FAA taken any action to this point? We issued a proposal to
amend part 39 of the Federal Aviation Regulations (14 CFR part 39) to
include an AD that would apply to all Dornier Models 228-100, 228-101,
228-200, 228-201, 228-202, and 228-212 airplanes that have windshield
spray nozzle option SCN 3109 installed.
This proposal was published in the Federal Register as a notice of
proposed rulemaking (NPRM) on October 26, 2000 (65 FR 64176). The NPRM
proposed to require you to deactivate the windshield spray nozzle
heating elements.
Was the public invited to comment? Interested persons were afforded
an opportunity to participate in the making of this amendment. We have
given due consideration to the comment received.
Comment Disposition
What is the commenter's concern? Dornier requests that FAA withdraw
the AD because no airplanes on the U.S. Register have windshield spray
nozzle option SCN 3109 installed and, therefore no airplanes are
subject to the AD.
What is FAA's response to the concern? We do not concur. Although
there may not be any airplanes on the U.S. Register that have this
installation, the AD is still justified. Issuing an AD is the only way
to assure that:
--The installation is not incorporated on any U.S.-registered airplane
in the future; or
--The actions are accomplished on any airplane that is imported from
another country and placed on the U.S. Register.
We have not changed the AD as a result of this comment. We have
modified the Cost Impact section of this document to reflect the
information that Dornier provided.
The FAA's Determination
What is FAA's Final Determination on this Issue? After careful
review of all available information related to the subject presented
above, we have determined that air safety and the public interest
require the adoption of the rule as proposed except for minor editorial
corrections. We determined that these minor corrections:
--Will not change the meaning of the AD; and
--Will not add any additional burden upon the public than was already
proposed.
Cost Impact
How many airplanes does this AD impact? We estimate that 9
airplanes in the U.S. registry could have windshield spray nozzle
option 3109 installed. Based on information received from Dornier, none
of these 9 airplanes incorporate this option.
Therefore, this AD imposes no cost impact at this time on U.S.
owners/operators of these airplanes. The following presents cost data
if an airplane with this option installed was imported from another
country and placed on the U.S. Register:
----------------------------------------------------------------------------------------------------------------
Labor cost Parts cost Total cost per airplane
----------------------------------------------------------------------------------------------------------------
1 workhour x $60 per hour = $60.... Not applicable............... $60 per airplane.
----------------------------------------------------------------------------------------------------------------
Regulatory Impact
Does this AD impact various entities? The regulations adopted
herein will not have a substantial direct effect on the States, on the
relationship between the national government and the States, or on the
distribution of power and responsibilities among the various levels of
government. Therefore, it is determined that this final rule does not
have federalism implications under Executive Order 13132.
Does this AD involve a significant rule or regulatory action? For
the reasons discussed above, I certify that this action (1) is not a
``significant regulatory action'' under Executive Order 12866; (2) is
not a ``significant rule'' under DOT Regulatory Policies and Procedures
(44 FR 11034, February 26, 1979); and (3) will not have a significant
economic impact, positive or negative, on a substantial number of small
entities under the criteria of the Regulatory Flexibility Act. A copy
of the final evaluation prepared for this action is contained in the
Rules Docket. A copy of it may be obtained by contacting the Rules
Docket at the location provided under the caption ADDRESSES.
List of Subjects in 14 CFR Part 39
Air transportation, Aircraft, Aviation safety, Safety.
Adoption of the Amendment
Accordingly, under the authority delegated to me by the
Administrator, the Federal Aviation Administration amends part 39 of
the Federal Aviation Regulations (14 CFR part 39) as follows:
PART 39--AIRWORTHINESS DIRECTIVES
1. The authority citation for part 39 continues to read as follows:
Authority: 49 U.S.C. 106(g), 40113, 44701.
Sec. 39.13 [Amended]
2. FAA amends Sec. 39.13 by adding a new AD to read as follows:
2001-04-04 Dornier Luftfahrt Gmbh: Amendment 39-12122; Docket No.
99-CE-19-AD.
(a) What airplanes are affected by this AD? This AD affects
Models 228-100, 228-101, 228-200, 228-201, 228-202, and 228-212
airplanes, all serial numbers, that:
(1) are certificated in any category; and
(2) have windshield spray nozzle option SCN 3109 installed.
(b) Who must comply with this AD? Anyone who wishes to operate
any of the above airplanes must comply with this AD.
(c) What problem does this AD address? The actions specified by
this AD are intended to prevent the windshield spray nozzle heating
system from overheating, which could result in smoke in the cockpit
and prompt the crew to initiate emergency actions.
(d) What actions must I accomplish to address this problem? To
address this problem, you must accomplish the following:
[[Page 10965]]
------------------------------------------------------------------------
Action Compliance time Procedures
------------------------------------------------------------------------
(1) Deactivate the Within the next 100 Dornier All
windshield spray nozzle hours time-in- Operators Telefax
heating elements by cutting service (TIS) after (AOT) No. AOT-228-
wire ME16F20 at the splice April 6, 2001 (the 30-022, dated
at frame 7. Cap (MS2574-2 effective date of September 9, 1998,
caps) and stow cables. this AD), unless references this
already action.
accomplished.
(2) Do not install, on any As of April 6, 2001 Not Applicable.
affected airplane, (the effective date
windshield spray nozzle of this AD).
option SCN 3109.
------------------------------------------------------------------------
(e) Can I comply with this AD in any other way? You may use an
alternative method of compliance or adjust the compliance time if:
(1) Your alternative method of compliance provides an equivalent
level of safety; and
(2) The Manager, Small Airplane Directorate, approves your
alternative. Submit your request through an FAA Principal
Maintenance Inspector, who may add comments and then send it to the
Manager, Small Airplane Directorate.
Note 1: This AD applies to each airplane identified in paragraph
(a) of this AD, regardless of whether it has been modified, altered,
or repaired in the area subject to the requirements of this AD. For
airplanes that have been modified, altered, or repaired so that the
performance of the requirements of this AD is affected, the owner/
operator must request approval for an alternative method of
compliance in accordance with paragraph (e) of this AD. The request
should include an assessment of the effect of the modification,
alteration, or repair on the unsafe condition addressed by this AD;
and, if you have not eliminated the unsafe condition, specific
actions you propose to address it.
(f) Where can I get information about any already-approved
alternative methods of compliance? Contact Karl M. Schletzbaum,
Aerospace Engineer, FAA, Small Airplane Directorate, 901 Locust,
Room 301, Kansas City, Missouri 64106; telephone: (816) 329-4146;
facsimile: (816) 329-4090.
(g) What if I need to fly the airplane to another location to
comply with this AD? The FAA can issue a special flight permit under
sections 21.197 and 21.199 of the Federal Aviation Regulations (14
CFR 21.197 and 21.199) to operate your airplane to a location where
you can accomplish the requirements of this AD.
(h) How do I get copies of the documents referenced in this AD?
You may obtain copies of the documents referenced in this AD from
Dornier Luftfahrt GmbH, Product Support, P.O. Box 1103, D-82230
Wessling, Federal Republic of Germany; telephone: (08153) 302631;
facsimile: (08153) 304463. You may examine these documents at FAA,
Central Region, Office of the Regional Counsel, 901 Locust, Room
506, Kansas City, Missouri 64106.
Note 2: The subject of this AD is addressed in German AD Number
1999-030/2, dated April 8, 1999.
(i) When does this amendment become effective? This amendment
becomes effective on April 6, 2001.
Issued in Kansas City, Missouri, on February 8, 2001.
Michael Gallagher,
Manager, Small Airplane Directorate, Aircraft Certification Service.
[FR Doc. 01-4048 Filed 2-20-01; 8:45 am]
BILLING CODE 4910-13-P
Source: Official FAA Source ↗
Retrieved: Apr 6, 2026
Rights: U.S. Government Public Domain
This site is not affiliated with or endorsed by the FAA. Always verify with official sources.